DNA Sequencing Facility
The DNA Sequencing Facility uses Idea Infinity Elan software for sample submission and to streamline ordering and billing. Please refer to the Sample Submission page for guidelines on how to use the software
Overview
- High throughput, automated DNA sequencing services are currently provided for by
the use of the state of the art Applied Biosystems 3730 DNA Analyzer. This capillary
based instrument has the capability to run up to 48 samples in one run with read
lengths of greater that 1,000 bases (PHRED Q20 scores >800) within 2 hours.
- Big Dye Terminator (BDT) v 3.1 Chemistry is currently in use. This chemistry is
an improvement upon the original BDT v 3.0 chemistry in that it allows the operator
to achieve longer read lengths, even in the presence of G rich templates. Several
cycle sequencing optimization strategies are available at the DNA Sequencing Facility
for problematic templates.
Equipment
- Applied Biosystems 3730 DNA Analyzer
- MJ Research Tetrad Thermocyclers
Services Provided
- Fluorescent DNA sequencing of plasmids, PCR products, cosmids, Phage, BAC, and Genomic
DNA
- SNP Analysis
- Methylation Status Detection
- Primer Walking Projects including Primer Design, Contig Assembly and Consensus Sequence
Generation
- High Throughput DNA Sequencing Projects
Please email:
DNASequencing@ohri.ca regarding the services provided, or to discuss options for high throughput analysis.
Sample Preparation
As the Applied Biosystems 3730 DNA Analyzer has an increased magnitude of sensitivity
over previous models of sequencers, results obtained with this instrument are highly
dependent upon both template quality and quantity.
The single most important determinant of a successful sequencing reaction is the
presence of a high quality template. DNA that is suitable for restriction analysis
or manual DNA sequencing may not produce optimal results with the 3730. Here are
some points to consider:
-
The two most common contaminants that will adversely affect your results are EDTA
and salt. All sequencing templates submitted should be prepared using a high quality
isolation protocol (Qiagen and Millipore methods recommended). Additionally, all
templates should be resuspended in either MilliQ H2O, or 10 mM Tris-HCl pH 8.0.
For long-term storage, 10 mM Tris is recommended.
The following list comprises contaminants that may be present in a sequencing template
along with the final amounts that may be tolerated in the reaction:
Contaminant
|
Final Amount Tolerated
|
RNA
|
1.0 µg
|
PEG
|
0.3%
|
NaOAC
|
0.5 mM
|
Ethanol
|
1.25%
|
Phenol
|
0%
|
CsCI
|
5.0 mM
|
EDTA
|
0.1 mM
|
Detergents (SDS, Triton X-100)
|
0%
|
- DNA quantity can also affect the quality of your sequencing results. Insufficient
amounts of DNA template can produce reactions that generate signals that are far
too low to be interpreted by the analysis software. This will be evidenced by a
reduced overall peak height with concomitant inability of the software to make a
call at low intensity base positions. Conversely, templates that are provided at
too high a concentration can result in data that is top heavy. That is, high signal
will be observed at the beginning of the sequence, followed by a gradual decrease
in peak height due to depletion of the fluorescently labelled ddNTPs. Fluorometric
or spectrophotometric determination of template concentration is strongly recommended.
- PCR fragments should be gel purified to ensure that all non-specific bands and primers
are removed.
Reaction Submission Format
Templates may be submitted to the facility between the hours of 8:00 am and 3:30
pm. The samples should be placed in the designated cooler
outside Lab CCW 5132 in the Sprott Centre for Stem Cell Research. In order to minimize error and reduce turnaround time we will only accept samples that are provided in the following format:
- Each reaction should be provided in a separate 1.5 ml microfuge tube, unless you have 18 or more samples which are loaded to a PCR plate)
- The microfuge tube should clearly be labelled with black indelible ink with the Sample Submission ID followed by Sample ID.
- Please ensure that the Sample ID number on the microfuge tube corresponds exactly to the number indicated on the sample submission form.
- If 47 or more samples are submitted at the same time please follow the instructions below
- Samples are to be provided in a 96-well PCR polypropylene plate and arranged as follows:
- Well A1 should be left empty for our internal control.
- The remaining the wells should be filled in the following order: B1 to H1, A2 to H2, A3 to H3, and so forth.
- Plate(s) should be submitted with primers added to the samples if applicable.
- Please notify the facility via DNASequencing@ohri.ca mentioning the service ID of the request for the discount to be applied.
- Reactions that require standard primers (provided by the Sequencing Facility) need to be provided at the concentration and amounts indicated for each template type. A separate template submission (separate microfuge tube) is required for each standard primer requested.
- Reactions that require custom primers (provided by the customer) need to be provided with the template and the primer pre-mixed in the same microfuge tube in the amounts indicated below for each template type.
- Samples from external sources should be shipped to the below mailing address via Federal Express or Purolator.
- All samples are processed on a first come first served basis.
- Laboratories will be charged for all reactions processed barring any technical issues encountered. For quality assessment purposes, one pGem control reaction will be included on each sequencing run. Periodic repeats of failed reactions will be performed to confirm the results.
- Results can generally be obtained within 2 working days from date of submission and will be forwarded by email.
- When your reactions have been completed you will receive an email containing both your sequencing text files (simple text format) and your electropherogram files.
- Please submit only the required amount as samples are not kept for long term storage and retrieval.
Researchers that require higher throughput sequencing may also submit their samples in 96 well PCR plate format. Please contact
DNASequencing@ohri.ca to inquire.
Reaction Specifications
Template Type
|
Template Concentration (ng/µl)
|
Template Volume (µl)
|
Custom Primer Concentration(µM)
|
Custom Primer Volume (µl)
|
PCR
|
1
|
10
|
2
|
5
|
Plasmid
|
12.5
|
10
|
2
|
5
|
Cosmid, Lambda Phage
|
50
|
12
|
2
|
8
|
BAC, Genomic DNA
|
Please amplify your target region by PCR, and submit the products for sequencing.
|
Fees
Affiliation |
Price Per Sample |
Internal Labs |
$9.00 |
External Academic Labs |
$10.00 |
Government Labs |
$12.00 |
Industry |
$18.00 |
Primer Specifications
The DNA Sequencing Facility provides the standard primers listed below free of charge.
Additional primers may be added to this list upon request. Please inquire.
- pUC/M13 Forward 5’{CGC CAG GGT TTT CCC AGT CAC GAC}3’
- pUC/M13 Reverse 5’{TCA CAC AGG AAA CAG CTA TGA C}3’
- SP6 5’{GAT TTA GGT GAC ACT ATA G}3’
- T3 5’{ATT AAC CCT CAC TAA AGG GA}3’
- T7 Promoter 5’{TAA TAC GAC TCA CTA TAG GG}3’
- T7 Terminator 5’{GCT AGT TAT TGC TCA GCG G}3’
- PGK Promoter 5'-3' {TTT GCT CCT TCG CTT TCT}
- EGFP-N 5'{CGT CGC CGT CCA GCT CGA CCA G}3'
- EGFP-C 5'{CAT GGT CCT GCT GGA GTT CGT G}3'
- CMV Forward 5'{AAA TGG GCG GTA GGC GTG}3'
- BGH Reverse 5'{TAG AAG GCA CAG TCG}3'
- SV40 Reverse 5'{GCG GGA CTA TGG TTG CTG AC}3'
- T20VN 5'{TTT TTT TTT TTT TTT TTT TTV N}
- (-21)M13F TGTAAAACGACGGCCAGT
- pFastBac Fwd TATTCCGGATTATTCATACCGTC
- pFastBac Rev GTATGGCTGATTATGATCCTC
Custom Primer Design
The choice of sequencing primer, method of primer synthesis, and approach to primer
purification can have a significant effect on the quality of the sequencing data.
The following list provides relevant considerations in sequencing primer design:
- Primers should be between 18-24 bases long to ensure good hybridization
- The GC content should range from 40-60%
- Primer Tm should be between 50-60 °C
- Primer design should only occur in regions of unambiguous sequence
- Avoid homopolymeric regions in primer design. This is especially true of G rich
regions as they can form secondary structures.
- The use of software for primer design is strongly recommended. Several good primer
design websites exist and include: